A front door’s data sheet lists a dozen or more coefficients, classes and thicknesses. To choose, you only need four: the thermal transmittance of the whole door (Ud), the burglar resistance class (RC), how the leaf and frame are built, and how the door is installed. Below: how to read them, what the regulations have required so far, and what to watch out for when replacing a door in an existing house.

Thermal insulation

The first figure is the thermal transmittance, U (the lower it is, the warmer the door). Manufacturers’ data sheets give two values: U for the panel (leaf) alone and Ud for the whole door, meaning the leaf together with the frame and threshold. Ud is the one that counts, because a noticeable share of heat escapes through the frame, threshold and seals, and the panel on its own usually scores clearly better than the complete door. The technical building regulations (warunki techniczne) have so far required external doors to have a Ud of no more than 1.3 W/(m²K); the 2002 regulation lost its legal basis on 20 September 2026, no replacement has been issued yet, and 1.3 remains the practical benchmark. When comparing offers, ask for the Ud for your specific door size, about the threshold design (warm, with a thermal break) and about the number of seals around the perimeter. Three seals feel very different from one.

Burglar resistance class

The RC class tells you how long a door holds out against a break-in attempt with specified tools. For a detached house, RC2 is the starting point; RC3 is chosen when the house is in an isolated spot or the insurer requires it. Just as important as the class are a multi-point lock (bolts in several places), hinges protected against forcing, and a cylinder that resists drilling and snapping. A door labelled ‘burglar-resistant’ with no class stated tells you nothing.

The RC class applies to a door installed according to the manufacturer’s instructions. An RC2 leaf in a frame that is poorly anchored, or held in place only by foam, can be forced like any ordinary door. Installing front doors is a job for an installation team that knows the system.

Aluminium or steel

Aluminium doors are light, dimensionally stable and stand up well to the sun, so they are usually the better choice for a south-facing elevation. Door profiles are reinforced and rigid; aluminium is not a ‘soft’ material here. Steel doors are heavier and usually cheaper for a similar RC class. The choice comes down to the elevation and your budget, as both types come in many designs.

A design that matches the gate and fence

Repeating a motif gives the best result: the same horizontal grooves on the door and the garage door, and the same colour (most often anthracite RAL 7016) as the fence. A vertical stainless steel inlay or an illuminated pull handle changes the look of the entrance without changing how the leaf is built. Wiśniowski offers matching door, garage door and fence designs and colours in its Home Inclusive line.

What to check before ordering

  • The opening direction and hinge side, given the layout of the entrance porch.
  • The clear passage width: will your furniture and appliances fit through?
  • Whether the threshold is warm and low (pushchairs, shopping, older people).
  • The Ud of the whole door and the RC class in the product sheet, for your specific size.
  • A colour match with the garage door, ideally from one manufacturer’s palette.

What to watch out for when replacing a door

When you replace a door in an existing house, the opening causes the most trouble: a frame left out of true by the old door, a threshold cast into the screed under the tiles, no room for a warm threshold. That’s why, before ordering, the opening is measured at three points across its width and its height, the floor levels inside and out are checked, and so is whether the new, thicker leaf will catch on the floor as it opens. The replacement itself usually takes one working day if the opening is ready; the manufacturer usually needs several weeks to make a door to measure.

The frame is fixed with anchors or frame plugs and sealed in layers (vapour-tight tape on the inside, foam, vapour-permeable tape on the outside) – what is known as warm installation. Without it, even a door with a very good Ud will let the cold in through the gap around the frame. You can’t see this layer once everything is finished, but it decides whether the porch stays warm and dry.

Sources

Legal position as of October 2026. General information, not legal advice.

Quote after a site survey

We’ll come out for a site survey and prepare a quote within 7 working days of it. There is a charge for the site survey because it covers travel, measurements including levels, and choosing the system; the cost is agreed individually and deducted from your order. Manufacturer’s warranty – Wiśniowski fences come with an anti-corrosion warranty of up to 10 years. The terms of our own installation warranty are set out in the quotation.