Call: +48 22 266 25 58
Wiśniowski winter promotion: garage doors with openers up to −25%, fences and doors up to −15%, orders by 31 DecemberGarage doors up to −25% · until 31 DecemberDetails ›
Home › Where we install › Piaseczno
Piaseczno municipality

Fences and gates in Piaseczno municipality: rules worth knowing before you order

Our office is in Chyliczki, within Piaseczno municipality. Here we’ve summarised what the landscape resolution, the local zoning plans and the road regulations mean for a fence around a detached house. This is general information taken from official documents. The final word always rests with the local zoning plan and the local authority for the specific plot.

Landscape resolution
no. 128/VII/2019
in force since 25 May 2019, across the whole municipality
Openness
min. 50%
fences around detached houses
Height
up to 1.8 m
around detached housing areas
Local zoning plans
almost 70% of the municipality
according to the Development Strategy to 2040
10 km20 kmWARSZAWAGóra KalwariaKonstancin-JeziornaLesznowolaPiasecznoBiuro ISS
Straight-line distance from our office in Chyliczki: approx. 3 km. The journey by road is longer.

Rules that apply across the whole municipality

Resolution no. 128/VII/2019 of Piaseczno Town Council of 13 March 2019 sets uniform rules for fences across the whole municipality. For a detached house, these are the key provisions:

WhatWhat the resolution says
OpennessAt least 50%. The degree of openness is the ratio of the area of the gaps to the total area of the fence.
Height1.8 m around areas whose main use is detached housing.
MaterialsFences made of precast concrete and reinforced concrete panels are banned (except precast elements for foundations or bases), as are corrugated and trapezoidal sheet metal fences (except on building sites). Sharp-pointed steel, glass and ceramic elements are banned.
Small animalsThe fence must allow them to pass through. The options are: point foundations, a base that does not protrude above ground level, or a base up to 0.3 m high with openings at ground level, at least 0.15 m in diameter or side length, spaced every 10 m.
Blocks of flatsThe resolution bans fencing off multi-family housing, whether individual buildings or groups of buildings.
ColourThe resolution doesn’t regulate it.
Existing fencesFences that existed on the day the resolution came into force do not have to be brought into line with it.

What this means when choosing a fence

A 50% openness requirement rules out solid fences, so it’s worth starting your choice of design with the percentage of open area of the specific fence panel, and only then looking at colour and infill. In many systems the spacing of the slats or bars can be chosen to meet this threshold, but each design has its own spacing. So the figure in the resolution applies to a specific fence panel, not to a whole category.

The base is planned together with the post foundations. You need to choose one of the three solutions for small animals from the outset, because it’s harder to add openings to a finished plinth than to leave them when pouring the concrete.

Local zoning plans can be stricter than the resolution

The municipality has local zoning plans for almost 70% of its area. Some of the plans from 2017 and 2018 have their own provisions on fences, different from or stricter than the landscape resolution:

PlanHeightOpen areaOther provisions
Józefosław, part I (2018)up to 1.8 mmin. 60% of the fence panel, or a hedgeSolid fences and fences made of precast reinforced concrete are banned. Plinth up to 0.6 m. Gates set back at least 5 m from the centre line of the carriageway on public roads narrower than 10 m. No fencing within 3 m of the bank of the Jeziorka Ditch (Rów Jeziorki).
Wólka Kozodawska (2017)up to 1.8 mmin. 60% of the whole areaPrecast concrete fence panels and poured concrete fences are banned. Base up to 0.6 m with 15 × 15 cm passages at least every 10 m. Gates set back at least 2 m from the boundary line of a road narrower than 10 m. Solid fences are permitted along ul. Dworska (noise).
Głosków, part I (2018)up to 2.0 mmin. 25% (wood, masonry, plastics) or 50% (metal) between posts above the plinthPlinth up to 60 cm with 15 × 15 cm openings at least every 10 m. Solid fences and fences with precast concrete panels are excluded.
Whether the provisions of a plan like this apply alongside the landscape resolution, or are superseded by it, is not clear for every plan. Głosków allows 2.0 m, the resolution 1.8 m. The safe option is to meet the stricter requirement and clear up any doubt with the Urban Planning and Architecture Department (Wydział Urbanistyki i Architektury) before you order the fence. Plans are also amended from time to time, so check the current wording for your plot.

Newer plans don’t have to repeat these rules. The plan for the village of Chyliczki (stage I, resolution no. 355/XXII/2025) contains no provisions on fences in its text, and the plan for part of the village of Julianów Północny (2022) refers directly to the landscape resolution. For plots within their boundaries, the rules in the resolution therefore apply.

Driveway access and gates on the road side

A driveway gate usually requires driveway access from a public road, and the access permit is issued by the road authority. Who that is depends on the category of road:

  • Municipal road: Piaseczno Town and Municipal Office (Urząd Miasta i Gminy Piaseczno), Mobility Policy Department. The municipality publishes a service information sheet listing the documents required (including a site development plan in 2 copies) and information on the stamp duty (opłata skarbowa).
  • County road: Piaseczno County Office (Starostwo Powiatowe w Piasecznie), Investment, Repairs and Roads Department, tel. +48 22 756 62 54.
  • Voivodeship road (including DW 721 and DW 722): Masovian Voivodeship Roads Authority (Mazowiecki Zarząd Dróg Wojewódzkich).
  • National road (DK 79): General Directorate for National Roads and Motorways (GDDKiA).

You can check the category of the road next to your plot on the municipal map, in the Mobility section. For access from a municipal road, the service sheet also requires traffic management plans for the period while the access is being built and for after it is completed.

Nature and water

Part of the municipality lies within the Chojnów Landscape Park (Chojnowski Park Krajobrazowy; regional assembly resolution no. 156/24 of 17 December 2024) and the Warsaw Protected Landscape Area. The resolution on the park contains no provisions on fences, but it bans the construction of new structures within 100 m of the banks of rivers, lakes and other natural bodies of water, with exceptions (including for land designated for development in local zoning plans). In the protected landscape area, a similar ban applies to a 20 m strip from the banks of rivers and lakes (100 m in the special ecological protection zone). Whether a fence is covered by these bans does not follow directly from their wording, so if your plot is by the Jeziorka, Zielona or Tarczynka, it’s worth asking the park office (tel. +48 22 754 51 00) before you order.

The park’s conservation plan recommends fences with open bases that let small animals through. Local plans, e.g. for Chyliczki and Wólka Kozodawska, also designate areas at particular risk of flooding. You can check their extent on the municipality’s geoportal.

Where to check the rules for your plot

The register shows that the Masovian Voivode (regional governor) has declared some planning resolutions invalid, so it’s worth checking the status of the plan for each plot.

Frequently asked questions

In Piaseczno municipality, does a front fence have to be see-through?
Yes. The landscape resolution requires fences around properties whose main use is detached housing to be at least 50% open, so solid fences are ruled out. A local zoning plan may require more, e.g. 60% in Józefosław and Wólka Kozodawska.
How high can the fence be?
The resolution sets 1.8 m around detached housing areas. Some plans have different values (e.g. 2.0 m in Głosków, part I), so you need to check what applies to your plot. Separately, the Construction Law (Prawo budowlane, Article 29) distinguishes between fences up to 2.20 m and higher ones, and the higher ones require a notification (zgłoszenie).
Can I have a base?
Yes, but in one of three forms: point foundations, a base that does not protrude above ground level, or a base up to 0.3 m high with openings for small animals (at least 0.15 m, spaced every 10 m). Local plans may allow a higher plinth, e.g. up to 0.6 m in Józefosław and Wólka Kozodawska.
Does a fence that has been standing for years have to be brought into line with the resolution?
No. The resolution states that fences existing on the day it came into force do not need to be brought into line. The requirements apply to new fences.
Where can I check which plan applies to my plot?
On the municipality’s geoportal (map of local zoning plans) and in the register of planning resolutions in the BIP. The official extract and map (wypis i wyrys) are issued by the municipal office.
Who do I apply to for driveway access from the road?
To the authority responsible for the road your plot is on: the municipality, the county, the voivodeship or GDDKiA. The road category is shown on the municipal map in the Mobility section.

Planning a fence or gate in Piaseczno municipality?

Email or call us. We’ll choose a system that meets the provisions that apply to your plot, and you can draw your frontage in the planner beforehand.