Driveway gate automation: motors, remotes, phone control
A driveway gate motor is chosen to suit the type of gate (sliding or double swing), the weight and length of the leaf, and how you want to control it: remote, keypad or phone. On top of that come photocells and a warning light, which are required with automatic closing. Below: what the kit includes, what to buy separately and what to prepare in the ground before the fence goes up.
Motors for sliding and double swing gates
- Sliding gate: one rack-driven motor mounted on the foundation footing next to the post. The gear rack runs along the bottom beam of the leaf.
- Double swing gate: articulated-arm or linear operators, one per leaf, or underground motors in boxes beneath the hinges.
The motor’s power is matched to the weight and length of the leaf using the motor manufacturer’s table. A motor that is too weak wears out faster and jams in winter; an oversized one costs more for no benefit. The installer sets the force and sensitivity during commissioning. Do not change the force settings. Adjustment with force measurement is a job for a service technician.
Photocells and warning light
Photocells stop the gate when a car, a person or a dog appears in the opening. The motor has obstruction detection, but this only reacts after contact with the leaf; photocells stop the gate sooner. With automatic closing (the gate closes by itself after a set time), photocells are required by the PN-EN 12453 standard. The warning light flashes while the gate is moving and warns pedestrians and drivers on the road.
Control
- Remote controls: the basics, one for each member of the household with a car. Remote codes are stored in the control unit’s non-volatile memory, so a power cut does not erase them.
- Keypad or reader: by the pedestrian gate or on a post, for members of the household without a remote and for guests with their own code.
- Smartphone control: a Wi-Fi or GSM module in the control unit. Open the gate remotely for a courier, check whether it is closed, and give someone access without handing over a remote.
- Video intercom in the post: see who is at the gate and open it from the monitor or an app.
Cabling before the fence goes up
The most expensive mistake is adding automation after the paving has been laid. Cable ducts, the power supply and the motor footing are planned together with the fence, while the trench is still open. The industry standard usually looks like this:
- a separate Ø40–50 mm conduit for the 230 V power supply and a separate one for signal cables (photocells, warning light, keypad, intercom);
- a power cable to the motor, e.g. YKY 3×1.5 mm², on a separate circuit in the consumer unit, with a 30 mA residual current device (RCD);
- ducts laid at a depth of at least 0.7 m, with warning tape above the cable;
- a duct under the driveway to the other side of the entrance (photocell, warning light on the catcher post) and to the pedestrian gate post if a keypad or intercom is to go there.
Cable sizes and depths are chosen by an electrician to suit the specific motor and the length of the run. The 230 V connection must be made by a qualified electrician.
Motor kit and extras
A standard kit usually includes the operator (or sliding gate motor), a control unit, two remotes, a pair of photocells and a warning light. That is enough for everyday use. It’s best to decide on extras before installation, because adding them later means reprogramming the control unit and sometimes running extra cables:
- Extra remotes: one per car and one for the house. You can buy them later, but they have to be paired with the control unit.
- Wi-Fi or GSM module: smartphone control and a view of the gate’s status.
- Backup battery: a few opening cycles during a power cut. Useful if the gate is the only way in.
- Wireless keypad: by the pedestrian gate or on the gate post, for members of the household without a remote.
- Multi-channel remote: one remote for the driveway gate and the garage door, if both motors use the same radio system.
When you order a driveway gate with automation, the list of extras and the control method are agreed before the motor footing is poured. A spare input on the control unit and a spare duct in the ground will save you breaking up the driveway a year or two later.
Frequently asked questions
Can automation be added to an existing gate?
In most cases, yes, provided the gate is in good working order, moves easily by hand and has a power supply. With old, heavy gates without proper guides, the mechanics need checking first: the hinges or roller carriages, the catcher and the geometry of the leaf.
How much electricity does a gate motor use?
Very little. On standby it draws a few watts, and the motor runs for a dozen or so seconds per cycle. Over a year, the cost is negligible. What matters is a stable power supply and a separate circuit breaker in the consumer unit.
Are photocells mandatory?
With automatic closing, yes: the PN-EN 12453 standard requires them. With impulse control from a remote, when the user can see the gate, the standard accepts force limitation alone, but obstruction detection only reacts after contact with the leaf. Photocells stop the gate before it touches a child, a bike or a car, which is why they are fitted to every motorised gate.
Quote after a site survey
We’ll come out for a site survey and prepare a quote within 7 working days of it. There is a charge for the site survey because it covers travel, measurements including levels, and choosing the system; the cost is agreed individually and deducted from your order. Manufacturer’s warranty – Wiśniowski fences come with an anti-corrosion warranty of up to 10 years. The terms of our own installation warranty are set out in the quotation.