A sliding gate spends years running on roller carriages bolted to a single foundation. If the foundation moves, the leaf starts to rub, doesn’t close as well and the motor has to work against more resistance. Below: what depth the manufacturers require, why their instructions differ, and what to check before the concrete arrives.

What the manufacturers’ instructions say

Foundation dimensions aren’t decided by eye or by the crew’s habits. The gate manufacturer specifies them in the installation instructions, and installation that doesn’t follow the instructions is one of the warranty exclusions. Two examples from systems we install:

ManufacturerDepthConcretePlan dimensions
Wiśniowski, residential sliding gateBelow the frost zone at the installation site, and no less than 120 cmC20/C25, compactedAs per the drawing and table in the instructions, depending on gate width
Konsport, cantilever gate up to 5.8 mAt least 1 m, adjusted to local frost depthAt least B20Footing 40 cm wide, half the gate’s clear opening in length

Sources: Wiśniowski’s instructions ‘Fundamentowanie – brama przesuwna posesyjna’ (Foundations – residential sliding gate, 09/2019) and Konsport’s installation instructions ‘Brama samonośna (do 5,8 m)’ (Cantilever gate, up to 5.8 m).

B20 is a concrete class under an older Polish standard. It still turns up in instructions, so it’s worth asking the concrete supplier for the equivalent.

Wiśniowski’s instructions also note that the drawing shows the minimum reinforcement, and that whether the foundation is built correctly depends on the ground and groundwater conditions. In special cases the foundation has to be properly designed. The work itself must comply with EN 1992 and EN 1997.

Why 120 cm for one and 1 m for the other

These are two different designs with two different sets of instructions. What applies is the set for the gate being installed – not an average of several sources or the ‘usual’ figure.

In Wiśniowski’s instructions, 120 cm is the minimum. If the ground freezes deeper at a given site, the foundation goes deeper. If the frost doesn’t reach that far, the foundation is still at least 120 cm deep.

Konsport’s instructions for a cantilever gate up to 5.8 m require a depth of at least 1 m and say the excavation depth should be adjusted to local frost depth. They also give the footing dimensions: 40 cm wide and half the gate’s clear opening long. So for a 4 m clear opening, the footing is 2 m long. It is poured on the side the gate opens towards, inside the property.

We set the depth at the site survey to suit the ground and the gate, and never shallower than the manufacturer requires.

What happens if the foundation is too shallow

Ground within the frost zone freezes and expands in winter, then thaws and settles in spring. A shallow foundation moves with it: it lifts, tilts or settles unevenly.

With a sliding gate you won’t notice straight away. Over time the carriages fall out of line, the leaf starts to rub or misses the end stop, and the motor works against more resistance. Adjusting the carriages won’t cure the problem if the foundation itself is moving.

The second problem is a cracked footing. Konsport’s instructions put this down to pouring concrete in unsuitable weather and state that the temperature must not be lower than −5°C when pouring. So the timing of the pour matters too.

Putting it right usually means taking the gate down, breaking out the old foundation and pouring a new one. Then there’s the warranty: Wiśniowski’s warranty card for fencing systems (version 05/2026) excludes installation that doesn’t follow the instructions.

What to check before pouring

  • Gate model. The foundation is built for a specific gate and its instructions, so you need to know the model before anyone starts digging.
  • Clear opening and direction of travel. These determine how long the foundation is and where it goes.
  • Finished driveway level. Wiśniowski’s instructions give dimensions relative to the finished driveway level, not the current ground level.
  • Foundation bolts. Depending on the gate version, Wiśniowski specifies two, three or four foundation bolts made from 500 mm lengths of ribbed bar. They are set vertically, with their tops at the same level.
  • Motor cables. For a motorised gate, the cables are brought out through the foundation before it is poured. Breaking into a fresh foundation is an unnecessary cost. Wiśniowski’s instructions call for 1 m of spare cable and photocell cables run in steel or PVC conduit, and give the cross-section of the 230 V supply cable: 3×1.5 mm², or 3×2.5 mm² where the power source is more than 30 m away. The installation must comply with PN-IEC 60364.
  • Room for the leaf to slide back. There must be no tree, utility connection box or lamp post along the stretch the gate slides along. Wiśniowski’s instructions calculate the leaf’s travel as the width between the posts plus the carriage spacing plus 400 mm, and the carriage spacing depends on the gate width.

Frequently asked questions

Can a new gate go on an old foundation?

Only if its depth and dimensions match the new gate’s instructions. You can’t see the depth from the surface, so at the site survey we work out whether it can be checked or whether it’s better to pour a new foundation.

How long do you have to wait after pouring the foundation?

According to Konsport’s instructions, the footing with the guide posts set in it is left for 14 days for the concrete to cure, and only then is the gate installed. For other manufacturers’ gates, the time given in their own instructions applies.

Does 120 cm also apply to fence and pedestrian gate posts?

The figures in this post apply to sliding gate foundations. Fence posts and pedestrian gates have their own requirements in the system instructions. There’s more on posts in How deep to set fence posts.

Quote after a site survey

We’ll come out to do a site survey and prepare a quote within 7 working days of the survey. There is a charge for the site survey, as it covers travel, measurements including levels and choosing the system; the cost is agreed individually and deducted from your order. Manufacturer’s warranty: for Wiśniowski fences, up to 10 years’ anti-corrosion warranty. The terms of our installation warranty are set out in the offer.